Name
seteuid, setegid — set effective user or group
ID
Synopsis
int
seteuid( |
uid_t |
euid); |
int
setegid( |
gid_t |
egid); |
DESCRIPTION
seteuid() sets the effective
user ID of the current process. Unprivileged user processes
may only set the effective user ID to the real user ID, the
effective user ID or the saved set-user-ID.
Precisely the same holds for setegid() with "group" instead of
"user".
RETURN VALUE
On success, zero is returned. On error, −1 is
returned, and errno is set
appropriately.
ERRORS
- EPERM
-
The current process is not privileged (Linux: does
not have the CAP_SETUID
capability in the case of seteuid(), or the CAP_SETGID capability in the case of
setegid()) and euid (resp. egid) is not the real
user (group) ID, the effective user (group) ID, or the
saved set-user-ID (saved set-group-ID).
CONFORMING TO
4.3BSD, POSIX.1-2001.
NOTES
Setting the effective user (group) ID to the saved
set-user-ID (saved set-group-ID) is possible since Linux
1.1.37 (1.1.38). On an arbitrary system one should check
_POSIX_SAVED_IDS.
Under libc4, libc5 and glibc 2.0 seteuid(euid) is equivalent to
setreuid(−1, euid) and hence may change the
saved set-user-ID. Under glibc2.1 it is equivalent to
setresuid(−1, euid, −1) and hence does not
change the saved set-user-ID. Similar remarks hold for
setegid().
SEE ALSO
geteuid(2), setresuid(2), setreuid(2), setuid(2), capabilities(7), credentials(7)
Copyright (C) 2001 Andries Brouwer (aeb@cwi.nl)
Permission is granted to make and distribute verbatim copies of this
manual provided the copyright notice and this permission notice are
preserved on all copies.
Permission is granted to copy and distribute modified versions of this
manual under the conditions for verbatim copying, provided that the
entire resulting derived work is distributed under the terms of a
permission notice identical to this one.
Since the Linux kernel and libraries are constantly changing, this
manual page may be incorrect or out-of-date. The author(s) assume no
responsibility for errors or omissions, or for damages resulting from
the use of the information contained herein. The author(s) may not
have taken the same level of care in the production of this manual,
which is licensed free of charge, as they might when working
professionally.
Formatted or processed versions of this manual, if unaccompanied by
the source, must acknowledge the copyright and authors of this work.
[should really be seteuid.3]
Modified, 27 May 2004, Michael Kerrisk <mtk-manpages@gmx.net>
Added notes on capability requirements
|